]> xenbits.xensource.com Git - qemu-xen.git/commitdiff
qemu-iotests: ignore leaks on failure paths in 026
authorVladimir Sementsov-Ogievskiy <vsementsov@virtuozzo.com>
Mon, 16 Sep 2019 17:53:20 +0000 (20:53 +0300)
committerMax Reitz <mreitz@redhat.com>
Thu, 10 Oct 2019 08:56:17 +0000 (10:56 +0200)
Upcoming asynchronous handling of sub-parts of qcow2 requests will
change number of leaked clusters and even make it racy. As a
preparation, ignore leaks on failure parts in 026.

It's not trivial to just grep or substitute qemu-img output for such
thing. Instead do better: 3 is a error code of qemu-img check, if only
leaks are found. Catch this case and print success output.

Suggested-by: Anton Nefedov <anton.nefedov@virtuozzo.com>
Signed-off-by: Vladimir Sementsov-Ogievskiy <vsementsov@virtuozzo.com>
Message-id: 20190916175324.18478-2-vsementsov@virtuozzo.com
Signed-off-by: Max Reitz <mreitz@redhat.com>
tests/qemu-iotests/026
tests/qemu-iotests/026.out
tests/qemu-iotests/026.out.nocache
tests/qemu-iotests/common.rc

index ffb18ab6b5adfc9aa3acf9329bf75a073851beb5..3430029ed69f40dd9877f6c6dd606f201fea5b0c 100755 (executable)
@@ -107,7 +107,7 @@ if [ "$event" == "l2_load" ]; then
     $QEMU_IO -c "read $vmstate 0 128k " "$BLKDBG_TEST_IMG" | _filter_qemu_io
 fi
 
-_check_test_img 2>&1 | grep -v "refcount=1 reference=0"
+_check_test_img_ignore_leaks 2>&1 | grep -v "refcount=1 reference=0"
 
 done
 done
@@ -152,7 +152,7 @@ echo
 echo "Event: $event; errno: $errno; imm: $imm; once: $once; write $vmstate"
 $QEMU_IO -c "write $vmstate 0 64M" "$BLKDBG_TEST_IMG" | _filter_qemu_io
 
-_check_test_img 2>&1 | grep -v "refcount=1 reference=0"
+_check_test_img_ignore_leaks 2>&1 | grep -v "refcount=1 reference=0"
 
 done
 done
@@ -191,7 +191,7 @@ echo
 echo "Event: $event; errno: $errno; imm: $imm; once: $once"
 $QEMU_IO -c "write -b 0 64k" "$BLKDBG_TEST_IMG" | _filter_qemu_io
 
-_check_test_img 2>&1 | grep -v "refcount=1 reference=0"
+_check_test_img_ignore_leaks 2>&1 | grep -v "refcount=1 reference=0"
 
 done
 done
index fb89b8480c31e0ae00f91e14e1412d87f39a75fa..ff0817b6f282e566ae8fc8d2d376a611f5074e42 100644 (file)
@@ -17,18 +17,14 @@ Event: l1_update; errno: 5; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l1_update; errno: 5; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l1_update; errno: 28; imm: off; once: on; write
@@ -45,18 +41,14 @@ Event: l1_update; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l1_update; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_load; errno: 5; imm: off; once: on; write
@@ -137,18 +129,14 @@ Event: l2_update; errno: 5; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_update; errno: 5; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_update; errno: 28; imm: off; once: on; write
@@ -165,18 +153,14 @@ Event: l2_update; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_update; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_alloc_write; errno: 5; imm: off; once: on; write
@@ -200,9 +184,7 @@ Event: l2_alloc_write; errno: 5; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l2_alloc_write; errno: 28; imm: off; once: on; write
@@ -226,9 +208,7 @@ Event: l2_alloc_write; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: write_aio; errno: 5; imm: off; once: on; write
@@ -480,18 +460,14 @@ Event: refblock_alloc_hookup; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-55 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_hookup; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-251 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_write; errno: 28; imm: off; once: on; write
@@ -532,18 +508,14 @@ Event: refblock_alloc_write_blocks; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_write_blocks; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_write_table; errno: 28; imm: off; once: on; write
@@ -560,18 +532,14 @@ Event: refblock_alloc_write_table; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_write_table; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_switch_table; errno: 28; imm: off; once: on; write
@@ -588,18 +556,14 @@ Event: refblock_alloc_switch_table; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: refblock_alloc_switch_table; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 
 === L1 growth tests ===
 
@@ -658,9 +622,7 @@ Event: l1_grow_activate_table; errno: 5; imm: off; once: off
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-96 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824
 
 Event: l1_grow_activate_table; errno: 28; imm: off; once: on
@@ -672,9 +634,7 @@ Event: l1_grow_activate_table; errno: 28; imm: off; once: off
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-96 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 
 === Avoid cluster leaks after temporary failure ===
 
index 6dda95dfb40719a12bdef51f50b46b900a66dbd7..495d013007cd3c4e11ed88e61b22efb53adb865f 100644 (file)
@@ -17,18 +17,14 @@ Event: l1_update; errno: 5; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l1_update; errno: 5; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l1_update; errno: 28; imm: off; once: on; write 
@@ -45,18 +41,14 @@ Event: l1_update; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l1_update; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_load; errno: 5; imm: off; once: on; write 
@@ -140,9 +132,7 @@ qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 wrote 131072/131072 bytes at offset 0
 128 KiB, X ops; XX:XX:XX.X (XXX YYY/sec and XXX ops/sec)
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_update; errno: 5; imm: off; once: off; write -b
@@ -150,9 +140,7 @@ qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 wrote 131072/131072 bytes at offset 0
 128 KiB, X ops; XX:XX:XX.X (XXX YYY/sec and XXX ops/sec)
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_update; errno: 28; imm: off; once: on; write 
@@ -172,9 +160,7 @@ qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 wrote 131072/131072 bytes at offset 0
 128 KiB, X ops; XX:XX:XX.X (XXX YYY/sec and XXX ops/sec)
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_update; errno: 28; imm: off; once: off; write -b
@@ -182,9 +168,7 @@ qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 wrote 131072/131072 bytes at offset 0
 128 KiB, X ops; XX:XX:XX.X (XXX YYY/sec and XXX ops/sec)
-
-127 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_alloc_write; errno: 5; imm: off; once: on; write 
@@ -208,9 +192,7 @@ Event: l2_alloc_write; errno: 5; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l2_alloc_write; errno: 28; imm: off; once: on; write 
@@ -234,9 +216,7 @@ Event: l2_alloc_write; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-1 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: write_aio; errno: 5; imm: off; once: on; write 
@@ -488,18 +468,14 @@ Event: refblock_alloc_hookup; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-55 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_hookup; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-251 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_write; errno: 28; imm: off; once: on; write 
@@ -540,18 +516,14 @@ Event: refblock_alloc_write_blocks; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_write_blocks; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_write_table; errno: 28; imm: off; once: on; write 
@@ -568,18 +540,14 @@ Event: refblock_alloc_write_table; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_write_table; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_switch_table; errno: 28; imm: off; once: on; write 
@@ -596,18 +564,14 @@ Event: refblock_alloc_switch_table; errno: 28; imm: off; once: off; write
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-10 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: refblock_alloc_switch_table; errno: 28; imm: off; once: off; write -b
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-23 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 
 === L1 growth tests ===
 
@@ -666,9 +630,7 @@ Event: l1_grow_activate_table; errno: 5; imm: off; once: off
 qemu-io: Failed to flush the L2 table cache: Input/output error
 qemu-io: Failed to flush the refcount block cache: Input/output error
 write failed: Input/output error
-
-96 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 Formatting 'TEST_DIR/t.IMGFMT', fmt=IMGFMT size=1073741824 
 
 Event: l1_grow_activate_table; errno: 28; imm: off; once: on
@@ -680,9 +642,7 @@ Event: l1_grow_activate_table; errno: 28; imm: off; once: off
 qemu-io: Failed to flush the L2 table cache: No space left on device
 qemu-io: Failed to flush the refcount block cache: No space left on device
 write failed: No space left on device
-
-96 leaked clusters were found on the image.
-This means waste of disk space, but no harm to data.
+No errors were found on the image.
 
 === Avoid cluster leaks after temporary failure ===
 
index e45cdfa66be8d9ddf3d03da392a990feef96c3d1..12b47518485db0a30bee528c2deb7bf983074091 100644 (file)
@@ -405,6 +405,23 @@ _check_test_img()
             $QEMU_IMG check "$@" -f $IMGFMT "$TEST_IMG" 2>&1
         fi
     ) | _filter_testdir | _filter_qemu_img_check
+
+    # return real qemu_img check status, to analyze in
+    # _check_test_img_ignore_leaks
+    return ${PIPESTATUS[0]}
+}
+
+_check_test_img_ignore_leaks()
+{
+    out=$(_check_test_img "$@")
+    status=$?
+    if [ $status = 3 ]; then
+        # This must correspond to success output in dump_human_image_check()
+        echo "No errors were found on the image."
+        return 0
+    fi
+    echo "$out"
+    return $status
 }
 
 _img_info()