if ( !is_x86_user_segment(seg) )
{
- bool lm = (desc.b & (1u << 12)) ? false : ctxt->lma;
+ /*
+ * Whether to use an 8- or 16-byte descriptor in long mode depends
+ * on sub-mode, descriptor type, and vendor:
+ * - non-system descriptors are always 8-byte ones,
+ * - system descriptors are always 16-byte ones in 64-bit mode,
+ * - (call) gates are always 16-byte ones,
+ * - other system descriptors in compatibility mode have
+ * - only their low 8-byte bytes read on Intel,
+ * - all 16 bytes read with the high 8 bytes ignored on AMD.
+ */
+ bool wide = desc.b & 0x1000
+ ? false : (desc.b & 0xf00) != 0xc00 &&
+ ctxt->vendor != X86_VENDOR_AMD
+ ? mode_64bit() : ctxt->lma;
- if ( lm )
+ if ( wide )
{
switch ( rc = ops->read(sel_seg, (sel & 0xfff8) + 8,
&desc_hi, sizeof(desc_hi), ctxt) )
default:
return rc;
}
+ if ( !mode_64bit() && ctxt->vendor == X86_VENDOR_AMD &&
+ (desc.b & 0xf00) != 0xc00 )
+ desc_hi.b = desc_hi.a = 0;
if ( (desc_hi.b & 0x00001f00) ||
(seg != x86_seg_none &&