int i, val;
/*
- * a maximum reset cycle time of 56 ms was measured.
- * we round it up to 100 ms
+ * in some rare cases the reset takes quite a long time
+ * especially when the channel is changed.
+ * Allow up to one second for it
*/
for (i = 0; i < 100; i++) {
val = gpiod_get_value(hx711_data->gpiod_dout);
if (!val)
break;
- /* sleep at least 1 ms */
- msleep(1);
+ /* sleep at least 10 ms */
+ msleep(10);
}
if (val)
return -EIO;
* after a dummy read we need to wait vor readiness
* for not mixing gain pulses with the clock
*/
- ret = hx711_wait_for_ready(hx711_data);
- if (ret)
- return ret;
+ val = hx711_wait_for_ready(hx711_data);
}
return val;