The xc_domain_getinfo does not clear the info structure before filling
it in, and in some circumstances it doesn't completely fill in the
structure for each domain. In particular, it sets the crashed flag if
the domain has crashed, but does not clear it if the domain has not
crashed, so the crashed flag may be random stack garbage from the
calling program. With the attached patch (against the latest nightly),
xc_domain_getinfo zeroes the array of info structures before filling
them in.

Signed-off-by: Josh Triplett <josht@us.ibm.com>
author kaf24@firebug.cl.cam.ac.uk
date Thu Jun 23 09:15:41 2005 +0000 (2005-06-23)
parents 84b9630129d7
children e1627c8b4e45
files tools/libxc/xc_domain.c
line diff
     1.1 --- a/tools/libxc/xc_domain.c	Thu Jun 23 09:13:44 2005 +0000
     1.2 +++ b/tools/libxc/xc_domain.c	Thu Jun 23 09:15:41 2005 +0000
     1.3 @@ -79,6 +79,8 @@ int xc_domain_getinfo(int xc_handle,
     1.4      dom0_op_t op;
     1.5      int rc = 0; 
     1.6  
     1.7 +    memset(info, 0, max_doms*sizeof(xc_dominfo_t));
     1.8 +
     1.9      for ( nr_doms = 0; nr_doms < max_doms; nr_doms++ )
    1.10      {
    1.11          op.cmd = DOM0_GETDOMAININFO;